Datalogic Matrix 320 2MP е стационарен индустриален четец на баркодове за автоматизирано четене на етикети, идентификация на директна маркировка върху детайли и проследимост на конвейери в производството и логистиката. Неговият сензор с резолюция 1920 × 1080 пиксела, конфигурируемото осветление и оптиката с течна леща или C-mount поддържат проследяването на компоненти, проверките за печат и залепване и идентификацията на пакети.
The Matrix 320 2MP captures barcode data at a fixed scanning point, identifying parts, cartons and logistics units as they pass through production or handling equipment. It suits applications that need a стационарен баркод скенер with selectable optics, adjustable lighting and connections to machine controls.
Supported applications include printed labels and direct part marking (DPM), where a code is marked directly onto the component. Reading performance depends on the code dimensions, surface finish, illumination and time available to capture and decode each image.
The 16:9 sensor format provides a wide horizontal image. The actual field of view—the area visible to the reader—depends on the lens and mounting distance. Covering a larger area spreads the available pixels over more surface, so small codes may require a narrower view or a higher-resolution reader.
| Спецификация | Matrix 320 2MP |
|---|---|
| Имиджов сензор | 1/3-inch CMOS global shutter; 1920 × 1080 pixels; 16:9 format |
| Заснемане на изображения | Up to 60 frames per second; completed reading cycles depend on exposure, decoding workload and configuration |
| Supported codes | 1D, stacked, 2D and postal formats, including GS1-128, Data Matrix ECC 200, QR Code, Micro QR, PDF417, Aztec and DotCode |
| Liquid Lens options | 6 mm, 9 mm and 16 mm with electronic focus adjustment |
| Published Liquid Lens reading ranges | 6 mm: 50–550 mm; 9 mm: 35–1,000 mm; 16 mm: 70–1,500 mm, subject to code size and optical setup |
| C-Mount optics | Interchangeable lenses with manual focus; Datalogic options from 4 mm to 35 mm |
| Комуникация | 10/100/1000 Mbit/s Ethernet, main RS-232/RS-422 full-duplex, auxiliary RS-232 and Datalogic ID-NET |
| Industrial Ethernet protocols | PROFINET IO, EtherNet/IP and Modbus TCP; TCP/IP, UDP and FTP are also supported |
| Digital connections | Two opto-coupled inputs, including an external trigger input; three configurable NPN, PNP or push-pull outputs |
| Захранване | 24 V DC ±10%; supply sizing must accommodate the selected illumination and peak current |
| Protection | IP65 and IP67 with correctly fitted lens cover, seals and suitable cables |
| Работна температура | Liquid Lens: 0 to 45 °C. C-Mount: −10 to 50 °C on applicable models; bodies 938100071 and 938100101: 0 to 50 °C. |
| Liquid Lens dimensions, H × W × L | 14-LED version: approximately 109 × 54 × 56 mm; 36-LED version: approximately 115.5 × 126 × 70 mm, with connectors at 0° |
The published reading ranges span different focus settings; they are not the depth of field available at one setting. Depth of field is the distance interval within which a particular code remains readable without refocusing. Check the smallest code at the nearest and farthest object positions before selecting the lens.
Liquid Lens models offer 14-LED or 36-LED illumination. The 6 mm versions have red or blue lighting options; 9 mm and 16 mm versions also offer white. Lighting colour is selected through the model or illuminator configuration, while supported LED groups and intensity can be adjusted during setup.
For reflective packaging or marked metal components, lighting angle and optional polarising covers can be as important as sensor resolution. Test representative parts, including low-contrast marks and variable surface finishes, to determine whether integrated lighting is sufficient or a C-Mount configuration with different illumination is needed.
The processing tier and lens type are separate choices. Standard X models address general industrial reading tasks, while Premium XP models provide additional processing capacity for demanding decoding workloads and applications that use several image settings.
Premium processing does not increase the sensor resolution. Assess its value using representative codes, the required cycle time and the number of images processed per item; a faster processor alone does not determine conveyor capacity.
Liquid Lens suits installations where focus needs to change during commissioning or product changeovers. Electronic adjustment allows focus settings to be changed remotely. Reading objects at several distances still requires an appropriate acquisition sequence and enough time for the selected images.
C-Mount suits installations requiring a particular focal length, aperture or lighting arrangement. The lens, protective cover, illumination and mounting components must be specified together. Check lens clearance and sensor coverage when considering third-party optics; the mount type alone does not establish suitability.
Datalogic’s Windows-based DL.CODE software supports image setup, decoding configuration and output formatting. Integrated aiming, the X-Press button interface and automatic setup functions assist commissioning. Web monitoring and FTP image saving support diagnostics, including investigation of failed reads.
For PLC integration, define the trigger source, expected data, communication protocol and response to an unreadable or incorrect code. Passing results into a warehouse management system, manufacturing execution system or ERP also requires a compatible host interface and application logic.
Specify the power and communication cables, mounting bracket, connection box where required, and any external trigger or illumination. Allow space for connector rotation and cable bends, and follow the mounting and heat-dissipation requirements for the operating temperature.
Обмислете Datalogic Matrix 320 5MP when the required reading area leaves too few pixels across the smallest code on a 2MP image. Compare both configurations at the same working distance, code size and required reading area.
| Фактор на подбор | Matrix 320 2MP | Matrix 320 5MP |
|---|---|---|
| Разделителна способност на изображението | 1920 × 1080 pixels | 2560 × 1936 pixels |
| Published acquisition rate | Up to 60 frames per second | Up to 25 frames per second |
| Optical configurations | Liquid Lens electronic focus or C-Mount manual focus | C-Mount manual focus |
| Illumination formats | 14 or 36 LEDs on Liquid Lens models; configurable lighting for C-Mount assemblies | 36-LED or 72-LED illumination options |
The 2MP model favours applications that benefit from electronic focus adjustment or more frequent image acquisition. The 5MP model provides more image detail for a given reading area. Neither frame-rate figure represents a specified number of parcels or successful decodes per second.
In its documented Sofprint Group PLC case study, MarvelTech installed a Matrix 320 with a 2MP sensor and Liquid Lens on a pharmaceutical packaging line in Sofia. The project combined barcode reading with triggering, product-data checks and machine controls, with images of detected errors saved for analysis.
The case study reports operation at 400 metres per minute for that installation. This is a project-specific result: another line requires assessment of code size, motion, exposure, lighting and trigger timing before a comparable operating speed can be specified.
It can read an applied barcode and support comparison with expected data. Code-quality metrics are also available, but production reading and quality monitoring are distinct from calibrated barcode verification. If a customer requires a formal verification report, specify the applicable standard and acceptance criteria before choosing the equipment.
One reader can capture multiple visible codes when they fit within its usable field of view and resolution. Labels on other faces, obscured codes or excessive distance variation may require additional readers or a different scanning arrangement. Define which codes belong to each pallet and how duplicate or unrelated reads will be handled.
The quotation depends on the standard or Premium reader, lens, illuminator, filters, protective covers, cables and mounting hardware. Application testing, installation, control-system integration and ongoing support should be itemised where required. Confirm availability, lead time, warranty terms and service coverage for the selected configuration and installation location.
MarvelTech provides automatic-identification integration, equipment maintenance and support services. For a configuration recommendation, send representative barcode images or samples, the smallest bar or cell size, surface material, working-distance range, required reading area, conveyor speed or cycle time, and the number of codes per item.
Include the PLC or host-system details, preferred communication protocol, installation location and photographs of the scanning area. Use the enquiry form to request a Matrix 320 2MP quotation covering the reader, accessories and required project services.
The Matrix 320 2MP suits fixed barcode-reading stations for component traceability, packaging checks, conveyor identification and hands-free order processing. It reads formats including GS1-128, Data Matrix and QR Code. Selection depends on whether the smallest code remains visible and readable throughout the required scanning area. Labels on opposite faces or hidden behind other items may require additional readers or controlled product presentation.
Choose Liquid Lens when remote focus adjustment is useful during commissioning or product changeovers. Choose C-Mount when the application needs a particular lens, aperture or illumination arrangement. Liquid Lens provides electronic focus adjustment; C-Mount lenses require manual adjustment. Neither choice alone establishes the usable depth of field, so assess the nearest and farthest code positions with the selected optics.
Datalogic lists Liquid Lens reading ranges of 50–550 mm for 6 mm optics, 35–1,000 mm for 9 mm and 70–1,500 mm for 16 mm. These ranges cover different focus settings, rather than simultaneous readability across the entire interval. The usable distance depends on code size, contrast and lighting. Specify the smallest bar or cell size alongside the required mounting distance.
Обмислете Datalogic Matrix 320 5MP when small codes need more image detail within a large reading area. The 2MP model remains relevant where its resolution is sufficient and electronic focus adjustment is useful. Compare configurations using the same code samples and required coverage: additional pixels cannot compensate for an obscured label, unsuitable lighting or motion blur.
Yes, suitable configurations can read direct part marks and reflective labels, but lighting selection is critical. DPM means the code is marked directly onto the component. Evaluate illumination colour, angle and optional polarising covers using actual materials and surface finishes. Lighting colour depends on the selected hardware; software-adjustable intensity does not mean every reader can switch between red, blue and white illumination.
Premium XP models provide greater processing capacity than standard X models, making them worth assessing for demanding decoding tasks or sequences using several image settings. Premium processing does not increase the 2MP sensor resolution. Compare the time needed to produce a valid result using representative codes; exposure, focus changes and communication also contribute to the complete reading cycle.
There is no single conveyor-speed figure applicable to every installation. Its specified 60 frames per second describes image acquisition, not successful reads or packages per second. Marveltech’s Sofprint packaging-line case study reports operation at 400 metres per minute for that installation. Another application needs assessment of exposure, code dimensions, spacing, lighting and trigger timing at the intended speed.
It can read an applied barcode and support checking its contents against expected product or order data. Available code-quality metrics can also help monitor printing changes. Successful decoding, correct data and formal barcode-quality verification are separate requirements. If you need a verification report, specify the grading standard, calibration requirements and report format before selecting the complete solution.
Yes. Supported industrial Ethernet protocols include PROFINET IO, EtherNet/IP and Modbus TCP, alongside serial interfaces and digital inputs and outputs. PLC integration requires agreed triggering, result formats and responses to missing or incorrect codes. Connecting a warehouse management system or manufacturing execution system additionally requires a compatible receiving interface and application logic that associates each result with the correct item.
Datalogic’s Windows-based DL.CODE software configures image acquisition, decoding and output data. Web monitoring and FTP image saving support diagnostics. During commissioning, configure which images and results to retain so technicians can distinguish a missing label from poor focus, glare or incorrect triggering. Image storage requires a suitable destination and retention plan; enabling diagnostics alone does not establish an archive.
The reader is rated IP65 and IP67 when assembled with the specified lens cover, seals and suitable connected cables. Liquid Lens models operate from 0 to 45 °C; C-Mount temperature limits depend on the reader-body part number. Check the exact configuration for colder installations. Follow heat-dissipation requirements near the upper temperature limit, and account for contamination that could obscure the optical window.
Request an itemised configuration covering the reader, lens, illumination, covers, mounting, power supply and cables, plus any trigger sensor or connection box. Send sample codes, minimum bar or cell size, distance limits, conveyor speed, item spacing and host-system details. Specify whether you need application testing or industrial automation integration services, and request current lead time and warranty terms for the quoted equipment.